Iteration Summary Error Message
Scenario
You are trying to download/analyze a report from the Report option and AIQ displays the following message: "An error has occurred while trying to retrieve the test duration. Iteration Summary may not be available or accurate."
Selected Report Option
Message
Solution / Workaround
This situation can happen when the URL of the RDS database server is changed (or even the password), the parameter config=default used to access the reports, needs to be changed with a config=<db-config-hash-number> and then the reports are accessible.
The <db-config-hash-number> can be obtained by inspecting the URL opened by the link “Click here to see reports” seen in the playback-controller.html page when running a scenario. That number does not change unless you change something in the AIQ database URL or DB user creds.
Process
Last updated: July 28, 2023